Superimposed code
Template:More footnotes In control theory the Youla–Kučera parametrization (also simply known as Youla parametrization) is a formula that describes all possible stabilizing feedback controllers for a given plant P, as function of a single parameter Q.
Details
The YK parametrization is a general result. It is a fundamental result of control theory and launched an entirely new area of research and found application, among others, in optimal and robust control.[1]
For ease of understanding and as suggested by Kučera it is best described for three increasingly general kinds of plant.
Stable SISO Plant
Let be a transfer function of a stable Single-input single-output system (SISO) system. Further, let Ω be a set of stable and proper functions of s. Then, the set of all proper stabilizing controllers for the plant can be defined as
where is an arbitrary proper and stable function of s. It can be said, that parametrizes all stabilizing controllers for the plant .
General SISO Plant
Consider a general plant with a transfer function . Further, the transfer function can be factorized as
, where M(s), N(s) are stable and proper functions of s.
Now, solve the Bézout's identity of the form
where the variables to be found (X(s), Y(s)) must be also proper and stable.
After proper and stable X, Y were found, we can define one stabilizing controller that is of the form . After we have one stabilizing controller at hand, we can define all stabilizing controllers using a parameter Q(s) that is proper and stable. The set of all stabilizing controllers is defined as
General MIMO plant
In a multiple-input multiple-output (MIMO) system, consider a transfer matrix . It can be factorized using right coprime factors or left factors . The factors must be proper, stable and doubly coprime, which ensures that the system P(s) is controllable and observable. This can be written by Bézout identity of the form
After finding that are stable and proper, we can define the set of all stabilizing controllers H(s) using left or right factor, provided having negative feedback.
where K(s) is an arbitrary stable and proper parameter.
The engineering significance of the YK formula is that if one wants to find a stabilizing controller that meets some additional criterion, one can adjust Q such that the desired criterion is met.
References
43 year old Petroleum Engineer Harry from Deep River, usually spends time with hobbies and interests like renting movies, property developers in singapore new condominium and vehicle racing. Constantly enjoys going to destinations like Camino Real de Tierra Adentro.
- D. C. Youla, H. A. Jabri, J. J. Bongiorno: Modern Wiener-Hopf design of optimal controllers: part II, IEEE Trans. Automat. Contr., AC-21 (1976) pp319–338
- V. Kučera: Stability of discrete linear feedback systems. In: Proceedings of the 6th IFAC. World Congress, Boston, MA, USA, (1975).
- C. A. Desoer, R.-W. Liu, J. Murray, R. Saeks. Feedback system design: the fractional representation approach to analysis and synthesis. IEEE Trans. Automat. Contr., AC-25 (3), (1980) pp399–412
- John Doyle, Bruce Francis, Allen Tannenbau. Feedback control theory. (1990). [1]