A '''total ionic strength adjustment buffer''' (''TISAB'') is a [[buffer solution]] which increases the [[ionic strength]] of a solution to a relatively high level. This is important for [[potentiometry|potentiometric]] measurements, including [[ion selective electrode]]s, because they measure the [[activity (chemistry)|activity]] of the analyte rather than its concentration. TISAB essentially masks most chemical interferences in the analyte solution and hence increases the accuracy of the reading.
The writer is known by [http://citymama.com.ua/profile_info.php?ID=38588 over the counter std test] name of Figures Wunder. Puerto Rico is where he's been living for many years and he will never transfer. Supervising is my occupation. One of the things she enjoys most is to study comics and she'll be starting something else alongside with it.
 
==Theory==
TISAB is very commonly applied to fluoride ion analysis such as in fluoride ion selective electrodes.
 
There are four main constituents to TISAB, namely CDTA (cyclohexylenedinitrilotetraacetate), sodium hydroxide, sodium chloride and acetic acid (ethanoic acid), which are all dissolved in deionised water. Hence, TISAB has a density ~1.0 kg/L. Each constituent plays an important role in controlling the ionic strength and pH of the analyte solution, which may otherwise cause error and inaccuracy.
 
The activity of a substance in solution depends on the product of its concentration and the activity coefficient in that solution. The activity coefficient depends on the ionic strength of the solution in which the potentiometric measurements are made.  This can be calculated for dilute solutions using the [[Debye-Hückel equation]]; for more concentrated solutions other approximations must be used.  In most cases, the analyst's goal is simply to make sure that the activity coefficient is constant across a set of solutions, with the assumption that no significant [[ion pair|ion pairing]] exists in the solutions.
 
Example:  An ion-selective electrode might be calibrated using dilute solutions of the analyte in distilled water.  If this calibration is used to calculate the concentration of the analyte in sea water (high ionic strength), significant error is introduced by the difference between the activity of the analyte in the dilute solutions and the concentrated sample.  This can be avoided by adding a small amount of ionic-strength buffer to the standards, so that the activity coefficients match more closely.
 
Adding a TISAB buffer to increase the ionic strength of the solution helps to "fix" the ionic strength at a stable level, making a linear correlation between the logarithm of the concentration of analyte and the measured voltage. By also adding the TISAB buffer to the samples from which the potentiometric equipment are calibrated, the linear correlation can be used to calculate the concentration of analyte in the solution.
 
:<math> E = K' + \frac{RT}{nF} \ln(c)</math>
where <math>E</math> is measured voltage, <math>R</math> is the gas constant, <math>T</math> the temperature measured in kelvins, <math>F</math> is the Faraday constant and <math>n</math> the charge of the analyte. <math>c</math> is the concentration of analyte.
 
TISAB buffers often include [[chelator]]s which bind ions that could otherwise interfere with the analyte.
 
{{DEFAULTSORT:Total Ionic Strength Adjustment Buffer}}
[[Category:Analytical chemistry]]
 
{{Analytical-chemistry-stub}}

Latest revision as of 01:17, 11 January 2015

The writer is known by over the counter std test name of Figures Wunder. Puerto Rico is where he's been living for many years and he will never transfer. Supervising is my occupation. One of the things she enjoys most is to study comics and she'll be starting something else alongside with it.